Venting Guide

Effective vent solutions, including vent cover filters, are crucial for controlling pressure, reducing condensation, and protecting sensitive components in automotive, industrial, medical, and consumer products. Properly designed vents and vent tubing maintain airflow while preventing vent condensation and contamination, extending the life of components, and enhancing system performance.

Vents can be installed manually on components and parts produced in low volumes, and automatically on components and parts manufactured on high-volume production runs.

How Vents Work

Venting, including vent caps, ventilation tubing, connectors, and ducting, allows controlled gas exchange between enclosures and the environment. Vented batteries, gas caps, and automotive components rely on microporous membranes to equalize pressure bi-directionally and prevent condensation and liquid ingress.

Microporous vent membranes, which include ventilation holes, are available in oleophobic and hydrophobic variations. Oleophobic membranes protect against oils, soaps, and low-surface-tension fluids, while hydrophobic membranes prevent water penetration.

Key Benefits of Proper Venting

  • Protects sensitive electronic and mechanical components from environmental damage.
  • Extends product lifespan by regulating internal pressure and preventing moisture buildup.
  • Reduces maintenance and downtime through reliable, contaminant-resistant venting solutions.
  • Enables design simplification by reducing reliance on heavy seals and housings.

Questions? Contact Us or Request a Quote

Automotive Applications

Why use venting in automotive applications?

Automotive equipment is often exposed to environmental changes such as temperature fluctuations, water, dirt, debris, and contact with automotive fluids. Proper venting, including vented caps, ensures:

  • Reliable protection from debris, dust, water, vent condensation, and automotive fluids.
  • Rapid pressure equalization to prevent component stress.
  • Reduced manufacturing costs and simplified component design by lessening the need for heavier seals, gaskets, and housings.
Typical automotive venting uses include:
  • Gas Caps
  • Sensors
  • Control units
  • Motors
  • Exterior Lighting
  • Powertrain Systems
  • Power Steering Systems

Venting in most automotive applications is designed to equalize pressure bi-directionally.

Specifically, the vent allows air to flow both in and out of a sealed enclosure such as a vented car battery. The need for bi-directional venting is driven by two key conditions: pressure buildup and vacuum creation. 

 

Bi-directional venting in automotive systems requires pressure relief and vacuum relief.

Pressure relief occurs when the internal pressure is higher than the external atmospheric pressure. Without a vent, pressure can damage seals and components or cause a tank to rupture. Rising temperatures cause liquids such as fuel or oil, or gases, to expand. The vent opens to release the excess pressure, preventing damage to the vehicle.

Vacuum relief occurs when the internal pressure is lower than the external atmospheric pressure. If the vacuum is not released, it can cause a tank to collapse or hinder the flow of fluids. This situation is common when the temperature drops, causing fluids and gases to contract, or when a fluid is drawn out of a container, like a fuel tank.

Examples

A fuel tank vent, which is part of the evaporative emissions control (EVAP) system, allows air to enter as fuel is consumed and allows air to exit as the tank is filled or as fuel vapor expands due to heat.

Without a vent, a fuel tank could collapse as fuel is used or rupture from pressure buildup. 

With engine crankcases, the Positive Crankcase Ventilation (PCV) system vents blow-by gases from the crankcase. Instead of releasing the pressurized gases, the PCV system re-routes gases back into the intake system to be reburned.

Additionally, fresh, filtered air is drawn into the crankcase through a breather hose to replace the blow-by gases being removed. During high-load conditions, the blow-by may also vent into the air intake. 

Additionally, fresh, filtered air is drawn into the crankcase through a breather hose to replace the blow-by gases being removed. During high-load conditions, the blow-by may also vent into the air intake. 

With battery enclosures, especially in electric vehicles (EVs), a battery vent allows for normal, continuous pressure equalization as the battery pack’s temperature and altitude change. This feature is crucial for maintaining the integrity of the enclosure’s seals.

In the event of a catastrophic thermal event, a separate, two-stage venting system provides safety with a much higher rate of pressure relief to prevent an explosion.

Industrial & Consumer Product Venting

Industrial and consumer products often face environmental exposure and require venting to maintain performance.
Examples include:
  • Diagnostic Venting. Telecommunications systems, solar energy systems, and heavy-duty equipment use venting to protect sensitive electronics from contaminants and liquids while promoting airflow and extending seal performance.
  • Outdoor Lighting Venting. Protects outdoor lighting equipment from moisture, dirt, dust, and pressure changes, improving reliability and service life.
  • Package Venting. Proper ventilation prevents container bloating, collapse, or leakage in agricultural, household, and industrial chemical products, reducing environmental and safety risks.
  • Sensor Protection. Smaller, more versatile sensors benefit from membranes that block contaminants, hazardous chemicals, and gases while stabilizing performance in fluctuating temperatures and pressures.

Medical & Specialty Applications

Medical and specialty equipment require precise venting to maintain safety and functionality. Examples include:

  • Medical Venting. Microporous membranes in medical devices allow airflow and pressure equalization, safely dissipating gases in liquids (e.g., intravenous (IV) fluid lines) while retaining liquids under pressure. This feature results in ventilator design, as well as in the design of other medical products, that have a long operating life.
  • Hydrophobic Barriers for Cameras & Electronics. Protects portable and underwater electronics against liquids, dust, and pressure changes.
  • Laboratory Equipment Protection. Maintains safe airflow, preventing contamination and ensuring equipment longevity.

Vent Membrane Design Considerations

When selecting a vent solution, consider the following:
  • Pressure Equalization. Does the vent membrane equalize pressure bi-directionally?
  • Contaminant Protection. Which liquids or particulates must the vent block?
  • Material Compatibility. Can the vent membrane withstand oils, chemicals, or temperature fluctuations?
  • Airflow Requirements. How quickly must the vent respond to oils, water, chemicals, particulate matter, or thermal events?
  • Durability. Can the vent membrane extend component life, reduce condensation, and control pressure effectively?

Common Test Methods

Several test methods are used to confirm the sealing integrity and structural strength of membranes and the larger systems they support.

The Pressure Decay Test (PDT) involves pressurizing a component with gas, typically air or nitrogen, then sealing it and measuring any drop in pressure over a set period. Minimal or no pressure loss indicates the membrane and seals are intact, while a significant drop signals a leak. The key performance metric is pressure loss over time.

The Vacuum Decay Test (VDT) works in the opposite direction. A vacuum is pulled on the membrane or component, and the rate at which the vacuum pressure rises is recorded. A slow or negligible pressure rise reflects good sealing integrity, whereas a rapid rise suggests a leak. The key metric is pressure rise over time.

The Bubble Point Test measures the minimum pressure required to push gas through a wetted membrane until a continuous stream of bubbles appears downstream. This “bubble point” corresponds to the largest pore in the membrane. A higher bubble point indicates smaller pores and greater resistance to pressure, confirming the pore size rating and filter integrity. The main metric is the pressure at which bubbles first appear.

The Hydrostatic Pressure Test assesses resistance to liquid penetration by subjecting the membrane to increasing water pressure, following standards such as ASTM D5385. The maximum water pressure the membrane can withstand without leakage defines its hydrostatic resistance, with pressure level and time to failure serving as the primary metrics.